Features:
- High Stopband Rejection
- Small Size
Band Reject Filter is a filter used in signal processing to suppress the magnitude of a signal within a specific frequency range while allowing signals in other frequency ranges to pass. The working principle of the band reject filter is to analyze the input signal in the frequency domain, and selectively suppress the amplitude of the signal according to the specified frequency range, so as to achieve noise reduction at the specified frequency.
1.Block signal transmission in a specific frequency range: the band-stop filter has no transfer function of zero, but has a transfer function minimum at the center cutoff frequency. Therefore, it can block the transmission of signals through its central frequency range.
2.Allow other frequency signals to pass: In addition to the center frequency range, the band-stop filter allows signals of all other frequencies to pass. This allows band-stop filters to be used to remove noise, interference and meet specific frequency response requirements.
3.Small wave distortion: compared with other types of filters, band-stop filters have smaller wave distortion. This means that it can better preserve the shape and amplitude of the signal passing through the filter.
4.Broadband signal processing: The band-stop filter can be used for the processing of broadband signals, because it can retain most of the frequency components and only block a specific frequency range.
5. Phase response: The phase response of a band-stop filter depends on its design and implementation, but is usually between a low-pass filter and a high-pass filter.
1. Electrical signal processing: Band stop filters can be used to filter out certain interference frequencies in electrical signal processing, thereby improving signal quality.
2. Radio communication: In radio communication, band stop filters can be used to filter out unnecessary frequencies in signals, thereby improving communication quality.
3. High frequency electronics: Band stop filters can be used to adjust the frequency response in circuits to achieve the required circuit performance.
4. Medical equipment: Band stop filters can be used in medical equipment, such as electrocardiogram instruments, to filter out frequencies from muscles and other external interference sources.
Qualwave supplies high stopband rejection band reject filters in frequency range DC-18GHz. The band reject filters are widely used in many applications.
Part Number |
Stopband(GHz, Min.) |
Stopband(GHz, Max.) |
Stopband Attenuation(dB) |
Passband(MHz) |
Passband(MHz) |
Insertion Loss(dB, Max.) |
VSWR(Max.) |
Connectors |
---|---|---|---|---|---|---|---|---|
QRF-47-68-45 | 47 | 68 | 45 | DC-32 | 95-1000 | 2 | 1.4 | SMA |
QRF-92-100-50 | 92 | 100 | 50 | 20-85 | 108-2000 | 2.5 | 1.5 | Φ0.38PIN |
QRF-600-700-45 | 600 | 700 | 45 | DC-500 | 800-2500 | 2 | 1.8 | SMA |
QRF-703-748-40 | 703 | 748 | 40 | DC-683 | 768-2000 | 1.5 | 1.5 | SMA |
QRF-791-821-50 | 791 | 821 | 50 | DC-773 | 839-2500 | 1.5 | 1.6 | SMA |
QRF-791-821-60 | 791 | 821 | 60 | DC-771 | 854-2400 | 1.2 | 1.7 | SMA |
QRF-824-849-40 | 824 | 849 | 40 | DC-809 | 864-2550 | 2 | 1.7 | SMA |
QRF-832-862-40 | 832 | 862 | 40 | DC-812 | 882-2400 | 1 | 1.5 | SMA |
QRF-832-862-60 | 832 | 862 | 60 | DC-812 | 895-2500 | 1.5 | 1.7 | SMA |
QRF-880-915-30 | 880 | 915 | 30 | DC-870 | 925-2500 | 2 | 1.5 | SMA |
QRF-880-915-40 | 880 | 915 | 40 | DC-865 | 930-2700 | 2 | 1.5 | SMA |
QRF-930-960-55 | 930 | 960 | 55 | DC-910 | 975-3000 | 3 | 2 | SMA |
QRF-1710-1785-40 | 1710 | 1785 | 40 | DC-1685 | 1810-4500 | 2 | 1.5 | SMA |
QRF-1710-1785-40-1 | 1710 | 1785 | 40 | DC-1695 | 1800-5100 | 3 | 1.5 | SMA |
QRF-1710-1785-60 | 1710 | 1785 | 60 | DC-1685 | 1810-5000 | 2 | 1.5 | SMA |
QRF-1785-1805-40 | 1785 | 1805 | 40 | DC-1755 | 1815-5200 | 2 | 2 | N |
QRF-1805-1880-60 | 1805 | 1880 | 60 | DC-1780 | 1905-5200 | 2typ. | 1.5typ. | SMA |
QRF-1805-1925-60 | 1805 | 1925 | 60 | DC-1755 | 1975-5000 | 2 | 1.5 | SMA |
QRF-1850-1910-60 | 1850 | 1910 | 60 | DC-1810 | 1950-5000 | 2 | 1.5 | SMA |
QRF-1880-1920-50 | 1880 | 1920 | 50 | DC-1860 | 1940-5800 | 2 | 1.5 | SMA |
QRF-1920-1980-35 | 1920 | 1980 | 35 | DC-1910 | 1990-6000 | 3 | 1.5 | SMA |
QRF-1920-1980-60 | 1920 | 1980 | 60 | DC-1895 | 2005-5400 | 1.7 | 1.5 | SMA |
QRF-2000-2300-50 | 2000 | 2300 | 50 | DC-1900 | 2400-5100 | 1.5 | 1.8 | SMA |
QRF-2010-2025-60 | 2010 | 2025 | 60 | DC-2000 | 2035-6000 | 4 | 1.5 | SMA |
QRF-2110-2170-60 | 2110 | 2170 | 60 | DC-2070 | 2210-6000 | 3 | 2 | SMA |
QRF-2200-2600-50 | 2200 | 2600 | 50 | DC-2080 | 2720-6000 | 1 | 1.8 | SMA |
QRF-2300-2400-40 | 2300 | 2400 | 40 | DC-2277 | 2423-6200 | 2 | 1.5 | SMA |
QRF-2300-2675-50 | 2300 | 2675 | 50 | DC-2200 | 2775-6200 | 1.5 | 1.8 | SMA |
QRF-2400-2483.5-50 | 2400 | 2483.5 | 50 | DC-2375 | 2510-7300 | 2.5 | 1.5 | SMA |
QRF-2400-2500-50 | 2400 | 2500 | 50 | DC-2350 | 2550-5500 | 1.5 | 1.5 | SMA |
QRF-2496-2690-50 | 2496 | 2690 | 50 | DC-2400 | 2790-5200 | 1 | 1.7 | SMA |
QRF-2500-2570-60 | 2500 | 2570 | 60 | 10-2450 | 2600-6000 | 1 | 2 | SMA |
QRF-2570-2620-55 | 2570 | 2620 | 55 | DC-2555 | 2635-4000 | 2 | 2 | SMA |
QRF-2575-2625-60 | 2575 | 2625 | 60 | DC-2550 | 2650-7700 | 2 | 1.5 | SMA |
QRF-2620-2690-60 | 2620 | 2690 | 60 | DC-2570 | 2740-10000 | 2 | 2 | SMA |
QRF-3300-3800-50 | 3300 | 3800 | 50 | DC-3190 | 3925-8500 | 1.2 | 1.7 | SMA |
QRF-3300-4200-50 | 3300 | 4200 | 50 | DC-3030 | 4470-8000 | 1 | 1.7 | SMA |
QRF-3400-3600-50 | 3400 | 3600 | 50 | DC-3300 | 3700-8000 | 2 | 1.7 | SMA |
QRF-3420-3700-60 | 3420 | 3700 | 60 | DC-3270 | 3850-8500 | 1.2 | 1.7 | SMA |
QRF-3600-3800-50 | 3600 | 3800 | 50 | DC-3500 | 3900-9200 | 1.2 | 1.7 | SMA |
QRF-4400-5000-50 | 4400 | 5000 | 50 | DC-4220 | 5150-10000 | 1 | 1.7 | SMA |
QRF-4800-4900-55 | 4800 | 4900 | 60 | DC-4720 | 4980-11000 | 2 | 1.7 | SMA |
QRF-5150-5350-50 | 5150 | 5350 | 50 | DC-5050 | 5450-11000 | 1.5 | 1.6 | SMA |
QRF-5150-5850-50 | 5150 | 5850 | 50 | DC-4950 | 6050-11500 | 1.5 | 1.7 | N |
QRF-5275-5850-50 | 5275 | 5850 | 50 | DC-5010 | 6115-11500 | 1.5 | 1.7 | SMA |
QRF-5470-5725-50 | 5470 | 5725 | 50 | DC-5350 | 5845-11000 | 1.3 | 1.7 | SMA |
QRF-5850-5925-50 | 5850 | 5925 | 50 | DC-5620 | 6170-18000 | 2 | 3 | SMA |
QRF-5925-6425-50 | 5925 | 6425 | 50 | DC-5700 | 6650-18000 | 2 | 3 | SMA |
QRF-5925-7125-50 | 5925 | 7125 | 50 | DC-5325 | 7725-18000 | 2 | 3 | SMA |
QRF-6425-6525-50 | 6425 | 6525 | 50 | DC-6300 | 6650-14000 | 2 | 1.7 | SMA |
QRF-6525-6875-50 | 6525 | 6875 | 50 | DC-6350 | 7050-14200 | 2 | 1.7 | SMA |
QRF-6875-7125-50 | 6875 | 7125 | 50 | DC-6700 | 7300-15000 | 2 | 1.7 | SMA |