page_banner (1)
page_banner (2)
page_banner (3)
page_banner (4)
page_banner (5)
  • RF  BroadBand EMC Low Noise Amplifiers
  • RF  BroadBand EMC Low Noise Amplifiers
  • RF  BroadBand EMC Low Noise Amplifiers
  • RF  BroadBand EMC Low Noise Amplifiers
  • RF BroadBand EMC Low Noise Amplifiers

    Features:

    • Broad Band
    • Low Noise

    Applications:

    • Wireless
    • Receiver
    • Laboratory Test
    • Radar

    A low noise amplifier is an amplifier with a very low noise figure, used in circuits to amplify weak signals and minimize the noise introduced by the amplifier.

    It is generally used as the high-frequency or intermediate frequency preamplifier of various Radio receiver, and the amplification circuit of high-sensitivity electronic detection equipment. A good Low-noise amplifier needs to amplify the signal while producing as low noise and distortion as possible.

    The following are the main Features and applications of low noise amplifiers:

    1. Gain amplification: LNA can amplify weak input signals to a sufficient level for subsequent circuit or system processing. In wireless communication, the received signal is often very weak, and through the amplification effect of LNA, the signal can be enhanced to a reliable level to provide subsequent processing and demodulation.
    2. Reduce system noise: LNA strives to minimize the introduction of additional noise while amplifying the signal. Noise is crucial for the performance of wireless communication systems as it can mask signals and reduce the signal-to-noise ratio of the system. A low noise amplifier reduces system noise by minimizing noise figure through the use of optimized circuit design and low noise materials.
    3. Improving the dynamic range of the system: Another function of LNA is to expand the dynamic range of the system. Dynamic range refers to the ability of a system to handle both strong and weak signals simultaneously. Low noise amplifiers can handle weaker signals without overloading or distortion due to stronger signals. This enables the system to work effectively in environments with large range of signal strength differences.

    The main application fields of LNA are wireless communication, medical equipment, measuring instruments, radar, satellite communication, etc.

    Qualwave supplies Low Noise Amplifiers from DC to 110GHz, and the noise figure can be as low as 0.7 dB. The minimum gain is 10dB and the maximum input VSWR is 3.5:1. We offer a variety of low noise amplifiers systems to meet all your needs to RF, microwave, and millimeter-wave amplifier components.

    img_08
    img_08

    Part Number

    Datasheet

    Frequency

    (GHz, Min.)

    xiaoyudengyu

    Frequency

    (GHz, Max.)

    dayudengyu

    Noise Figure

    (dBm, Max.)

    dengyu

    P1dB

    (dBm, Min.)

    dengyu

    Gain

    (dB, Min.)

    dengyu

    Gain Flatness

    (dB, typ.)

    dengyu

    Voltage

    (VDC)

    dengyu

    VSWR

    (Max.)

    xiaoyudengyu

    Lead Time

    (weeks)

    QLA-9K-3000-43-30 pdf 9K 3 3 16 43 1.5 12 1.8 2~8
    QLA-0.01-15000-12-60 pdf 0.00001 15 6(typ.) 10 12 2.5 12 2 2~8
    QLA-0.09-2000-42-30 pdf 0.00009 2 3(typ.) 15(typ.) 42(typ.) - 12 2(typ.) 2~8
    QLA-0.1-500-24-30 pdf 0.0001 0.5 3 5 24 0.5 15 1.5 2~8
    QLA-0.1-500-30-30 pdf 0.0001 0.5 3 5 30 0.5 5 1.5 2~8
    QLA-0.5-1000-23-12 pdf 0.0005 1 1.2(typ.) 23(typ.) 23(typ.) - 5 1.8(typ.) 2~8
    QLA-1-400-50-20 pdf 0.001 0.4 2 20 50 0.5 15 2 2~8
    QLA-1-12000-30-55 pdf 0.001 12 5.5(typ.) 15 30 2.5 12 2.5 2~8
    QLA-1-26500-17-55 pdf 0.001 26.5 5.5(typ.) 10 17 1 12 2.5 2~8
    QLA-1.6-30-13.5-42 pdf 0.0016 0.03 4.2 26 13.5 0.25 15 1.2 2~8
    QLA-5-1000-46-15 pdf 0.005 1 1.5(typ.) 20(typ.) 46(typ.) - 5 2(typ.) 0~4
    QLA-10-60-15-50 pdf 0.01 0.06 5 23 15 1 12 1.5 2~8
    QLA-10-60-16-50 pdf 0.01 0.06 5 23 16 1.5 5 - 2~8
    QLA-10-2500-30-40 pdf 0.01 2.5 4(typ.) 10 30 1 12 2 2~8
    QLA-10-18000-25-50 pdf 0.01 18 5 10 25 1 12 2.2 2~8
    QLA-20-3000-30-35 pdf 0.02 3 3.5 15 30 2.5 15 2 2~8
    QLA-20-6000-32-15 pdf 0.02 6 1.5(typ.) 12 32 1.5 5 2.5 2~8
    QLA-20-8000-20-30 pdf 0.02 8 3(typ.) 12 20 2 12 2(typ.) 2~8
    QLA-25-1000-50-13 pdf 0.025 1 1.3 14 50 - 5~20 2.5 2~8
    QLA-30-1000-15-20 pdf 0.03 1 2 18 15 3 5.5 2 2~8
    QLA-30-1000-50-13 pdf 0.03 1 1.3 15 50 2.5 12 1.5 2~8
    QLA-30-3000-40-30 pdf 0.03 3 3 12 40 2 15 2 2~8
    QLA-30-6000-25-50 pdf 0.03 6 5 10 25 3 15 2 2~8
    QLA-30-18000-15-25 pdf 0.03 18 2.5(typ.) 10 15 1 12 1.8 2~8
    QLA-50-90-15-32 pdf 0.05 0.09 3.2 10 15 0.2 15 1.5 2~8
    QLA-50-4000-20-15 pdf 0.05 4 1.5(typ.) 20(typ.) 20(typ.) 1.5 5 1.5(typ.) 2~8
    QLA-50-6000-25-40 pdf 0.05 6 4 22 25 3 12 2 2~8
    QLA-100-6000-16-10 pdf 0.1 6 1 21 16 8 5 2 2~8
    QLA-100-6000-25-25 pdf 0.1 6 2.5 15 25 2 12 1.5 2~8
    QLA-100-12000-25-25 pdf 0.1 12 2.5 15 25 2 12 1.5 2~8
    QLA-100-15000-45-22 pdf 0.1 15 2.2 5 45 2.5 12 1.5 2~8
    QLA-100-20000-25-40 pdf 0.1 20 4 20 25 1.5 12 3 2~8
    QLA-100-26500-30-30 pdf 0.1 26.5 3 20 30 2.5 12 2 2~8
    QLA-100-30000-18-55 pdf 0.1 30 5.5 15 18 2.5 12 2.5 2~8
    QLA-100-50000-28-50 pdf 0.1 50 5(typ.) 10 28 3.0(max.) 12 3 2~8
    QLA-200-2000-30-30 pdf 0.2 2 3 10 30 2 5 2 2~8
    QLA-200-6000-42-13 pdf 0.2 6 1.3 15 42 2 12 2 2~8
    QLA-200-10000-45-50 pdf 0.2 10 5 23 45 2.0(max.) 12 2.2 2~8
    QLA-300-40000-40-55 pdf 0.3 40 5.5(typ.) 14 40 2.5 12 2.5 2~8
    QLA-400-2000-25-20 pdf 0.4 2 2 20 25 1.5 9 2.5 2~8
    QLA-400-8000-40-25 pdf 0.4 8 2.5 14 40 1.5 12 2 2~8
    QLA-500-8000-20-16 pdf 0.5 8 1.6(typ.) 18(typ.) 20(typ.) 1 6 3.5 2~8
    QLA-500-18000-10-30 pdf 0.5 18 3(typ.) 12 10 1.5 15 2 2~8
    QLA-500-18000-14-30 pdf 0.5 18 3(typ.) 17 14 0.75 15 2 2~8
    QLA-500-18000-16-50 pdf 0.5 18 5 18 16 1.5(max.) 12 2.2 2~8
    QLA-500-18000-40-30 pdf 0.5 18 3 10 40 1.5 12 2.5 2~8
    QLA-500-18000-40-35 pdf 0.5 18 3.5 12 40 2 5 2 2~8
    QLA-500-40000-43-50 pdf 0.5 40 5 14 43 2.5 12 2 2~8
    QLA-600-4200-20-10 pdf 0.6 4.2 1(typ.) 21(typ.) 20(typ.) 2 5 2(typ.) 0~4
    QLA-600-4200-30-08 pdf 0.6 4.2 0.8 21 30 2.5 5 2 0~4
    QLA-600-4200-35-10 pdf 0.6 4.2 1 21 35 2 5 2 0~4
    QLA-600-4200-55-11 pdf 0.6 4.2 1.1 21 55 3 5 2 0~4
    QLA-700-1100-20-25 pdf 0.7 1.1 2.5 13 20 1 12 1.5 2~8
    QLA-700-1100-25-25 pdf 0.7 1.1 2.5 13 25 1.5 5 - 2~8
    QLA-800-18000-25-35 pdf 0.8 18 3.5 13 25 2.5 12 2 2~8
    QLA-950-2150-20-20 pdf 0.95 2.15 2 15 20 1.5 5 2 2~8
    QLA-1000-6000-15-20 pdf 1 6 2 12 15 4.5 5 2 2~8
    QLA-1000-12000-25-50 pdf 1 12 5(typ.) - 25 1.5(max.) 12 2 2~8
    QLA-1000-12000-28-30 pdf 1 12 3 15 28 1 12 2 2~8
    QLA-1000-18000-30-40 pdf 1 18 4 10 30 1.5 12 1.5 2~8
    QLA-1000-18000-40-32 pdf 1 18 3.2 8 40 2 5 1.8 2~8
    QLA-1000-18000-42-25 pdf 1 18 2.5 10 42 1.5 9 2 2~8
    QLA-1000-18000-45-30 pdf 1 18 3 10 45 2 5, 12 1.5 2~8
    QLA-1000-18000-47-25 pdf 1 18 2.5 10 47 1.5 9 2 2~8
    QLA-1000-18000-47-32 pdf 1 18 3.2 12 47 - 12 1.8 2~8
    QLA-1000-18000-50-30 pdf 1 18 3 20 50 2.5 12 2 2~8
    QLA-1000-18000-55-22 pdf 1 18 2.2 10 55 1.5 12 2.5 2~8
    QLA-1000-20000-25-35 pdf 1 20 3.5 21 25 2.5 12 2 2~8
    QLA-1000-20000-40-40 pdf 1 20 4 16 40 2 12 1.5 2~8
    QLA-1000-40000-30-80 pdf 1 40 8 10 30 3 12 2.5 2~8
    QLA-2000-6000-30-15 pdf 2 6 1.5 2 30 1 5 2 2~8
    QLA-2000-6000-39-45 pdf 2 6 4.5 23 39 0.8 10 2 2~8
    QLA-2000-8000-20-40 pdf 2 8 4 8 20 1.5 5 1.6 2~8
    QLA-2000-10000-30-40 pdf 2 10 4 15 30 1 12 2 2~8
    QLA-2000-18000-12-32 pdf 2 18 3.2 13 12 1.5 12 2 2~8
    QLA-2000-18000-18-30 pdf 2 18 3 10 18 1.5 12 1.5 2~8
    QLA-2000-18000-18-40 pdf 2 18 4 19 18 1 12 2 2~8
    QLA-2000-18000-21-40 pdf 2 18 4 23 21 1 12 2 2~8
    QLA-2000-18000-28-30 pdf 2 18 3 10 28 1.5 12 1.5 2~8
    QLA-2000-18000-30-45 pdf 2 18 4.5 10 30 2 12 2 2~8
    QLA-2000-18000-34-30 pdf 2 18 3 22 34 1.5 12 2.2 2~8
    QLA-2000-26500-25-40 pdf 2 26.5 4 8 25 2 12 1.8 2~8
    QLA-2000-26500-48-50 pdf 2 26.5 5 10 48 4.5 9 2.5 2~8
    QLA-3000-12000-24-30 pdf 3 12 3 21 24 1.5 12 1.5 2~8
    QLA-3000-15000-15-30 pdf 3 15 3 8 15 1 5 1.5 2~8
    QLA-4000-8000-22-25 pdf 4 8 2.5 14 22 1 12 2 2~8
    QLA-4000-8000-40-11 pdf 4 8 1.1 10 40 1.5 12 2 2~8
    QLA-4000-12000-14-30 pdf 4 12 3 15 14 2 12 2 2~8
    QLA-4000-12000-30-15 pdf 4 12 1.5 10 30 2 12 2 2~8
    QLA-5000-10000-30-23 pdf 5 10 2.3 10 30 1.2 5 1.5 2~8
    QLA-5400-5900-35-08 pdf 5.4 5.9 0.8 10 35 0.3 5 1.4 2~8
    QLA-6000-18000-20-28 pdf 6 18 2.8 13 20 1.2 12 2 2~8
    QLA-6000-18000-25-50 pdf 6 18 5 10 25 3 5 2 2~8
    QLA-6000-18000-50-30 pdf 6 18 3 15 50 1.5 12 2 2~8
    QLA-8000-12000-15-40 pdf 8 12 4 13 15 0.5 5 1.5 2~8
    QLA-8000-12000-32-11 pdf 8 12 1.1 10 32 1 12 2 2~8
    QLA-8000-18000-20-40 pdf 8 18 4 8 20 1.5 5 1.6 2~8
    QLA-8000-26500-15-35 pdf 8 26.5 3.5 8 15 1.5 5 1.5 2~8
    QLA-8000-26500-40-65 pdf 8 26.5 6.5 18 40 2 12 2 2~8
    QLA-9000-10000-25-15 pdf 9 10 1.5 20 25 0.5 9 1.8 2~8
    QLA-10700-12750-25-30 pdf 10.7 12.75 3 8 25 0.5 5 1.5 2~8
    QLA-12000-18000-20-40 pdf 12 18 4 15 20 1.5 12 1.5 2~8
    QLA-12000-18000-36-18 pdf 12 18 1.8 10 36 1.2 12 2 2~8
    QLA-12000-40000-30-40 pdf 12 40 4 5 30 2.5 12 2.5 2~8
    QLA-16000-22000-35-25 pdf 16 22 2.5 19 35 1.5 12 2 2~8
    QLA-16000-40000-20-35 pdf 16 40 3.5 16 18 3.5 5 2 2~8
    QLA-17500-20200-20-20 pdf 17.5 20.2 2 2 20 0.5 5 1.5 2~8
    QLA-17700-21200-30-80 pdf 17.7 21.2 8 10 30 2 15~24 2 2~8
    QLA-18000-26500-30-40 pdf 18 26.5 4 5 30 1 12 1.8 2~8
    QLA-18000-26500-48-25 pdf 18 26.5 2.5 10 48 2.5 12 2.3 2~8
    QLA-18000-26500-45-32 pdf 18 26.5 3.2 10 45 2 5 1.8 2~8
    QLA-18000-28000-20-40 pdf 18 28 4 8 20 1.5 5 1.6 2~8
    QLA-18000-40000-25-50 pdf 18 40 5 12 25 1.5(max.) 5 2.5 2~8
    QLA-18000-40000-25-50(P10) pdf 18 40 5 10 25 3 5 2 2~8
    QLA-18000-40000-25-50(P15) pdf 18 40 5 15 25 2.5 12 2 2~8
    QLA-18000-40000-30-50(P20) pdf 18 40 5 20 30 2.5 12 2.5 2~8
    QLA-18000-40000-30-35 pdf 18 40 3.5 8 30 2.5 12 2.2 2~8
    QLA-18000-40000-40-45 pdf 18 40 4.5 6 40 2.5 15 2 2~8
    QLA-18000-40000-50-45 pdf 18 40 4.5 5 50 3 15 2 2~8
    QLA-20000-32000-40-25 pdf 20 32 2.5 10 40 2.5 5 2 2~8
    QLA-23000-25000-35-20 pdf 23 25 2 -3 35 1.5 5 1.8 2~8
    QLA-23000-40000-34-35 pdf 23 40 3.5 10 34 2.5 12 2 2~8
    QLA-24000-28000-30-40 pdf 24 28 4 10 30 1 5 2 2~8
    QLA-24000-30000-30-20 pdf 24 30 2 10 30 1 5 1.5 2~8
    QLA-25300-27200-50-18 pdf 25.3 27.2 1.8 5 50 1 12 1.5 2~8
    QLA-26000-40000-30-28 pdf 26 40 2.8 10 30 2.5 12 2.3 2~8
    QLA-26000-40000-30-30 pdf 26 40 3 - 30 - 7 2.2 2~8
    QLA-26500-40000-20-30 pdf 26.5 40 3 5 20 1.5 5 1.5 2~8
    QLA-26500-40000-25-40 pdf 26.5 40 4 - 25 2 5 1.8 2~8
    QLA-39000-41000-30-32 pdf 39 41 3.2 10 30 0.5 5 2 2~8
    QLA-40000-53000-40-50 pdf 40 53 5 10 40 2 5 2 2~8
    QLA-50000-59000-40-55 pdf 50 59 5.5 10 40 1 8 2 2~8
    QLA-50000-75000-25-30 pdf 50 75 3 - 25 - 7 2 2~8
    QLA-57000-67000-30-50 pdf 57 67 5 10 30 - 12 2 2~8
    QLA-60000-90000-35-40 pdf 60 90 4 9 35 - 5 3 2~8
    QLA-60000-90000-26-43 pdf 60 90 4.3 - 26 - 7 2 2~8
    QLA-75000-110000-20.5-32 pdf 75 110 3.2 - 20.5 2.5 7 2 2~8
    QLA-75000-110000-38-36 pdf 75 110 3.6 - 38 - 7 2 2~8
    QLA-110000-170000-16-40 pdf 110 170 4(typ.) - 16 3 7 2.2 2~8
    QLA-140000-200000-15-45 pdf 140 200 4.5 - 15 3 7 2.5 2~8
    QLA-200000-230000-22-72 pdf 200 230 7.2 - 22 3 5 2.5 2~8
    QLA-230000-260000-19-85 pdf 230 260 8.5 - 19 - 5 3.5 2~8

    RECOMMENDED PRODUCTS

    • RF High Switching Speed High Isolation Test Systems SPST PIN Diode Switches

      RF High Switching Speed High Isolation Test Sys...

    • Voltage Controlled Oscillators (VCO)

      Voltage Controlled Oscillators (VCO)

    • RF High Switching Speed High Isolation Test Systems SP12T PIN Diode Switches

      RF High Switching Speed High Isolation Test Sys...

    • Dielectric Resonator Oscillators (DRO)

      Dielectric Resonator Oscillators (DRO)

    • RF High Sensitivity BroadBand Telecom Manual Phase Shifters

      RF High Sensitivity BroadBand Telecom Manual Ph...

    • Dielectric Resonantor Voltage Controlled Oscillator (Drvco)

      Dielectric Resonantor Voltage Controlled Oscill...