  • Medium Power Waveguide Terminations RF Microwave Loads
  • Medium Power Waveguide Terminations RF Microwave Loads
  • Medium Power Waveguide Terminations RF Microwave Loads
  • Medium Power Waveguide Terminations RF Microwave Loads
  • Medium Power Waveguide Terminations RF Microwave Loads

    Features:

    • Low VSWR

    Applications:

    • Transmitters
    • Antennas
    • Laboratory Test
    • Impedance Matching

    Medium Power Waveguide Terminations

    Medium Power Waveguide Termination is a passive component used to absorb medium power microwave signals. It is similar to low-power waveguide loads and is used to protect the normal operation of other components in microwave systems, avoid signal reflection, and improve system stability. However, compared to low-power waveguide loads, high-power waveguide terminations can absorb high-power microwave signals ranging from 100 watts to 1 kilowatt, with a frequency range of several hundred megahertz to up to 110GHz. Due to the high power loss of medium power waveguide loads, their internal temperature is high. To prevent load damage or overheating, a heat sink is usually needed to dissipate heat. The quality of RF Termination is determined by factors such as rated power, operating temperature, frequency bandwidth, and compatibility.

    Medium Power Waveguide Load has the following characteristics:

    1. High power resistance: The Medium Power Waveguide Termination is designed to withstand microwave signals at medium power levels. It can maintain stability under high-power signal loads, avoiding overload and damage.
    2. High reflection coefficient: Microwave Medium Power Waveguide Termination has a high reflection coefficient at the waveguide input end. It effectively reflects the signal inside the waveguide back to the source end, preventing the signal from continuing to transmit to the load end.
    3. Broadband: Medium Power Waveguide Terminations can operate over a wide frequency range and is suitable for various microwave systems with different frequencies.

    Medium Power Waveguide Termination is applied in the following areas:

    1. Microwave communication: Medium Power Waveguide Load can be used in waveguide networks in microwave communication systems, providing impedance matching and good signal termination for unused signals. It can improve the efficiency of the system and reduce signal interference.
    2. Microwave transmitter and receiver: Medium Power Waveguide Termination can be used for the input terminals of microwave transmitters and receivers. It can effectively absorb the power of the input signal, prevent signal reflection and interference with other electronic devices.
    3. Microwave testing and measurement: RF Termination is widely used in microwave testing and measurement, providing the correct load for the equipment to be tested. It can protect testing equipment from damage from excessive power signals and provide accurate test results.
    4. Microwave RF power amplifier: Microwave Termination can be used as the output terminal to terminate the load of microwave RF power amplifier. It can absorb the power of the amplifier output signal, prevent signal reflection and damage to the amplifier itself.

    Qualwave supplies low VSWR medium power waveguide terminations cover the frequency range 1.72~75.8GHz.

    img_08
    img_08

    Part Number

    Frequency

    (GHz, Min.)

    xiaoyudengyu

    Frequency

    (GHz, Max.)

    dayudengyu

    Power

    (W)

    xiaoyudengyu

    VSWR

    (Max.)

    xiaoyudengyu

    Waveguide Size

    dengyu

    Flange

    Lead Time

    (Weeks)

    QWT15-50 49.8 75.8 50 1.2 WR-15 (BJ620) FUGP620 0~4
    QWT19-50 39.2 59.6 50 1.2 WR-19 (BJ500) FUGP500 0~4
    QWT19-K6 39.2 59.6 600 1.2 WR-19 (BJ500) FUGP500 0~4
    QWT22-50 32.9 50.1 50 1.2 WR-22 (BJ400) FUGP400 0~4
    QWT28-50 26.3 40 50 1.2 WR-28 (B320) FBM320 0~4
    QWT28-K1 26.3 40 100 1.2 WR-28 (BJ320) FBP320 0~4
    QWT28-K25 26.5 40 250 1.2 WR-28 (B320) FBP320 0~4
    QWT34-K1 21.7 33 100 1.2 WR-34 (BJ260) FBP260 0~4
    QWT34-K5 21.7 33 500 1.15 WR-34 (BJ260) FBP260 0~4
    QWT42-K1 17.6 26.7 100 1.2 WR-42 (BJ220) FBP220 0~4
    QWT51-K1 14.5 22 100 1.2 WR-51 (BJ180) FBP180 0~4
    QWT62-K1 11.9 18 100 1.2 WR-62 (BJ140) FBP140 0~4
    QWT75-K5 10 15 500 1.2 WR-75 (BJ120) FBP120 0~4
    QWT75-K1 9.84 15 100 1.2 WR-75 (BJ120) FBP120 0~4
    QWT90-K1 8.2 12.5 100 1.2 WR-90 (BJ100) FBP100 0~4
    QWT90-K2 8.2 12.5 200 1.2 WR-90 (BJ100) FBP100 0~4
    QWT112-K15 6.57 10 150 1.2 WR-112 (BJ84) FBP84 0~4
    QWT137-K3 5.38 8.17 300 1.2 WR-137 (BJ70) FDP70 0~4
    QWT159-K3 4.64 7.05 300 1.2 WR-159 (BJ58) FDP58 0~4
    QWT187-K3 3.94 5.99 300 1.2 WR-187 (BJ48) FDP48 0~4
    QWT229-K3 3.22 4.9 300 1.2 WR-229 (BJ40) FDP40 0~4
    QWT284-K5 2.6 3.95 500 1.2 WR-284 (BJ32) FDP32 0~4
    QWT340-K5 2.17 3.3 500 1.2 WR-340 (BJ26) FDP26 0~4
    QWT430-K5 1.72 2.61 500 1.2 WR-430 (BJ22) FDP22 0~4
    QWTD180-K2 18 40 200 1.25 WRD-180 FPWRD180 0~4

    RECOMMENDED PRODUCTS

    • Standard Gain Horn Antennas RF  Microwave  Millimeter Wave Rectangular  Broadband

      Standard Gain Horn Antennas RF Microwave Mill...

    • 16 Way Power Dividers/Combiners RF Microwave Millimeter High Power Microstrip Resistive Broadband

      16 Way Power Dividers/Combiners RF Microwave M...

    • 10 Way Power Dividers/Combiners RF Microwave Millimeter High Power Microstrip Resistive Broadband

      10 Way Power Dividers/Combiners RF Microwave M...

    • Waveguide Switches Electromechanical Coax RF Double Ridge

      Waveguide Switches Electromechanical Coax RF Do...

    • Programmable Attenuators USB RF Digital Step USB Controlled

      Programmable Attenuators USB RF Digital Step US...

    • 24 Way Power Dividers/Combiners RF Microwave Millimeter High Power Microstrip Resistive Broadband

      24 Way Power Dividers/Combiners RF Microwave M...