page_banner (1)
page_banner (2)
page_banner (3)
page_banner (4)
page_banner (5)
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies
  • RF Cables and RF Cable Assemblies

    Features:

    • Low Insertion Loss
    • High Phase Stablity
    • High Power
    • High Durability

    Applications:

    • Laboratory Test
    • Avionics
    • Phase-array Radar
    • Satellite Communication

    RF cables are coaxial cables that are used to transmit high-frequency signals with minimal loss of signal strength.

    RF cable assemblies, on the other hand, are pre-assembled cable systems that consist of RF cables and connectors to provide a reliable and consistent transmission of high-frequency signals. The key features and applications of both RF cables and RF cable assemblies are as follows:

    Features:

    1. Low Signal Loss: RF cables and cable assemblies are designed to minimize signal loss and maintain signal quality over long distances.
    2. High Frequency Capability: These cables can transmit signals with frequency ranges from a few megahertz to several gigahertz.
    3. Shielding: RF cables and cable assemblies are shielded to minimize electromagnetic interference and ensure better signal quality.
    4. Durability: These cables and assemblies are built to withstand harsh environmental conditions, making them rugged and reliable.
    5. Versatility: RF cables and cable assemblies can be customized for various applications and can be made in a wide range of lengths and connector configurations.

    Applications:

    1.Telecommunications: RF cables and cable assemblies are extensively used in telecommunications applications, including cellular networks, Wi-Fi, and satellite communications.
    2. Aerospace and Defense: These cables and assemblies are used in military and aerospace applications, such as radar systems, missiles, and aircraft communication systems.
    3. Medical Equipment: RF cables and cable assemblies are used in various medical applications like CT scanners and MRI machines.
    4. Industrial Applications: RF cables and cable assemblies are used in industrial applications such as automated testing, control, monitoring, and measurement systems.
    5. Broadcast and Audio: RF cables and cable assemblies are used in broadcasting applications such as TV and radio transmission, recording studios, and live sound systems.

    Overall, RF cables and cable assemblies are crucial components in many high-frequency signal transmission systems as they offer high performance, flexibility, and durability. They are extensively used in various industries, including telecommunications, aerospace, medical equipment, and industrial automation, among others.

    Qualwave offers various RF Cables and RF Cable Assemblies to meet different requirements. Frequency range is from DC to 110GHz. Low insertion loss, high power handling, light weighted, and long life. Our cables are widely used in Avionics, Phased-array Radar, Laboratory Equipments, Base stations, etc.

    img_08
    img_08
    QT -High Performance Test Cable Assemblies
    Part Number Datasheet Frequency VSWR Shielding Phase Stability Temperature Bending Life Cycle Diameter Connectors Lead Time
    QT110 pdf DC~110 1.5 90 - -55~+125 50k 1.5 1.0mm 4~6
    QT67 pdf DC~67 1.5 90 ±7 -55~+125 100k 2.4 1.85mm, Mini-SMP, 2.4mm, 2.92mm, SMP 3~5
    QT50?(Hot) pdf DC~50 1.4 90 ±7 -55~+165 100k 3.6 2.4mm, 2.92mm, 3.5mm, SMA, N 2~3
    QTE – Economical Test Cable Assemblies
    Part Number Datasheet Frequency VSWR Shielding Phase Stability Temperature Bending / Mating Life Cycle Diameter Connectors Lead Time
    QTE pdf DC~18 1.3 90 - -55~+125 5k/5k 4 SMA, N 2~3
    QTF – Ultra-Flexible Test Cable Assemblies pdf
    Part Number Datasheet Frequency VSWR Shielding Phase Stability Temperature Bending / Mating Life Cycle Diameter Connectors Lead Time
    QTF pdf DC~26.5 1.3 90 - -55~+85 5k/5k 5.2 SMA, N 2~3
    QTV – VNA Test Cable Assemblies pdf
    Part Number Datasheet Frequency VSWR Phase Stability Amplitude Stability Bend Radius Connectors Lead Time
    QTV-V pdf DC~67 1.5 10 0.13 50 1.85mm 2~4
    QTV-2 pdf DC~50 1.42 8 0.1 50 2.4mm 2~4
    QTV-K pdf DC~40 1.35 6 0.1 50 2.92mm 2~4
    QTV-3 pdf DC~26.5 1.3 5 0.06 50 3.5mm 2~4
    QTV-N pdf DC~18 1.3 4 0.05 50 N 2~4
    QA – Ultra Low Loss & Phase Stable, Flexible Cables
    Part Number Datasheet Frequency Phase Change vs. Temp Shielding PIM Temperature Diameter Lead Time
    QA150 pdf DC~40 1000 90 -155 -55~+125 1.5 2~4
    QA220?(Hot)*1 pdf DC~50 750 90 -155 -55~+125 2.2 2~4
    QA300 pdf DC~50 750 90 -155 -55~+165 3.1 2~4
    QA360?(Hot) pdf DC~40 750 90 -155 -55~+165 3.6 1~2
    QA400 pdf DC~40 750 90 -155 -55~+165 4 1~2
    QA480 pdf DC~26.5 750 90 -155 -55~+165 4.8 1~2
    QA500?(Hot) pdf DC~26.5 750 90 -155 -55~+165 5.2 1~2
    QA550 pdf DC~18 750 90 -155 -55~+165 5.6 1~2
    QA750 pdf DC~18 750 90 -155 -55~+165 7.4 1~2
    QA760 pdf DC~18 750 90 -155 -55~+165 7.65 1~2
    QA800?(Hot) pdf DC~18 750 90 -155 -55~+165 7.9 1~2
    QA810 pdf DC~18 750 90 -155 -55~+165 8.1 1~2
    QA830 pdf DC~18 750 90 -155 -55~+165 8.3 1~2
    QB – Stable Loss, VSWR, Phase vs Flexing, Flexible Cables
    Part Number Datasheet Frequency Shielding PIM Temperature Diameter Lead Time
    QB1200 pdf DC~8 90 -155 -55~+200 12 1~2
    QB1500 pdf DC~6 90 -155 -55~+200 14.7 1~2
    QZ – Ultra-Flexible Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Lead Time
    QZ360 pdf DC~40 90 -55~+85 3.6 1~2
    QZ500 pdf DC~26.5 90 -55~+85 5 1~2
    QZ600 pdf DC~26.5 90 -55~+85 5.9 1~2
    QZ800 pdf DC~18 90 -55~+85 8 1~2
    QG – Low Loss, Flexible Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Lead Time
    QG360 pdf DC~18 70 -55~+125 3.6 1~2
    QG500 pdf DC~18 70 -55~+125 5.1 1~2
    QG800 pdf DC~18 90 -55~+125 8.1 1~2
    QY – High Weatherability, Low Loss, Flexible Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Outdoor Life Lead Time
    QY460 pdf DC~18 70 -55~+85 5 20 1~2
    QY520 pdf DC~18 70 -55~+85 6 20 1~2
    QY635 pdf DC~18 70 -55~+85 7.2 20 1~2
    QY1000 pdf DC~10 70 -55~+85 10.15 20 1~2
    QR – Low Loss Wiregreater Communication Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Outdoor Life Lead Time
    QR280 pdf DC-5.8 90 -40~+85 2.8 20 1~2
    QR500 pdf DC-5.8 90 -40~+85 5 20 1~2
    QR500U pdf DC-5.8 90 -40~+85 5 20 1~2
    QR600?(Hot) pdf DC-5.8 90 -40~+85 6 20 1~2
    QR600U pdf DC-5.8 90 -40~+85 6 20 1~2
    QR700 pdf DC-5.8 90 -40~+85 7.6 20 1~2
    QR1000?(Hot) pdf DC-5.8 90 -40~+85 10 20 1~2
    QR1000U pdf DC-2 90 -40~+85 10.3 20 1~2
    QR1500 pdf DC-5.8 90 -40~+85 15 20 1~2
    QR1500U pdf DC-2 90 -40~+85 15 20 1~2
    RG – Low Cost, Flexible Cables
    Part Number Datasheet Frequency Capacitance Temperature Diameter Lead Time
    RF113 pdf DC~6 98 -55~+200 1.13 1~2
    RF137 pdf DC~6 96 -55~+200 1.37 1~2
    RG178 pdf DC~6 96 -55~+200 1.8 1~2
    RG316 pdf DC~6 96 -55~+200 2.5 1~2
    RG179 pdf DC~3 64 -55~+200 2.54 1~2
    RG174 pdf DC~3 101 -20~+75 2.8 1~2
    RG316D pdf DC~6 95 -55~+200 2.9 1~2
    RG58 pdf DC~1 101.05 -40~+80 4.95 1~2
    RG142 pdf DC~12.4 95 -55~+200 4.95 1~2
    RG400 pdf DC~12.4 95 -55~+200 4.95 1~2
    RG223 pdf DC~6 100 -20~+80 5.4 1~2
    RG304 pdf DC~6 96 -55~+200 7.1 1~2
    RG6 pdf 0.005~2.2GHz 53 -20~+70 7.8 1~2
    QH – Flexible, Alternative to Semirigid Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Lead Time
    QH160 pdf DC~18 90 -55~+125 1.6 1~2
    QH280?(Hot)*1 pdf DC~40 90 -55~+125 2.65 1~2
    QH400?(Hot) pdf DC~26.5 90 -55~+125 4 1~2
    QE – Low VSWR and PIM, Semirigid Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Lead Time
    QE020 pdf DC-40 165 -55~+125 0.58 1~2
    QE047 pdf DC-40 165 -55~+125 1.2 1~2
    QE086 pdf DC-40 165 -55~+125 2.18 1~2
    QE141 pdf DC-26.5 165 -55~+125 3.58 1~2
    QD – Hand Formable, Semiflex Cables
    Part Number Datasheet Frequency Shielding Temperature Diameter Lead Time
    QD047 pdf DC-20 - -55~+200 1.19 1~2
    QD086 pdf DC-40 100 -55~+150 2.17 1~2
    QD141 pdf DC-6 100 -55~+150 3.55 1~2
    QD250 pdf DC-6 100 -55~+150 6.3 1~2
    QAM – RF Cable Armors
    Part Number Datasheet Diameter Inner Diameter Jacket Temperature Lead Time
    QAM0-40-U pdf 7.0±0.15 4.0±0.1 PUR -40~+80 1~2
    QAM0-54-N pdf 7.95±0.15 5.4±0.1 Nylon -40~+105 1~2
    QAM0-54-P pdf 7.55±0.15 5.4±0.1 PTFE -40~+165 1~2
    QAM0-54-U pdf 8.3±0.15 5.4±0.1 PUR -40~+80 1~2
    QAM0-62-N pdf 9.6±0.15 6.2±0.1 Nylon -40~+105 1~2
    QAM0-62-P pdf 9.15±0.15 6.2±0.1 PTFE -40~+165 1~2
    QAM0-62-U pdf 10.1±0.15 6.2±0.1 PUR -40~+80 1~2
    QAM0-80-N pdf 12.2±0.15 8.0±0.1 Nylon -40~+105 1~2
    QAM0-85-P pdf 12.5±0.15 8.5±0.1 PTFE -40~+165 1~2
    QAM0-85-U pdf 14.2±0.15 8.5±0.1 PUR -40~+80 1~2
    QAM1-22-P pdf 4.7±0.15 3.0±0.1 PTFE -40~+80 1~2
    QAM1-40-P pdf 6±0.15 4.0±0.1 PTFE -40~+165 1~2
    QAM1-62-P pdf 8.25±0.15 6.2±0.1 PTFE -40~+165 1~2

    RECOMMENDED PRODUCTS